About this item
A series of spectrophotometric colorimeters for colour grading of optically clear samples. Each version of the PFXi 195 includes a selection of standard colour scales that is used in a specific industry sector. Additional scales can be added, at the time of order or remotely, as optional upgrades, to provide the flexibility to meet individual requirements. Results can also be displayed in terms of spectral data and CIE values. For product types that are incompatible with the standard colour scales, the PFXi 195 software allows the users to build up a customised scale from a series of reference samples, and then to obtain the closest match to the stored reference.
- RCMSi provides calibration confidence and reduces on-site servicing and maintenance
- Consistent, reliable colour data removes operator subjectivity in colour grading
- Allows calculation and description of off-hue status
- Easily customised to user specification
- Accommodates a range of sample cells and tubes including standard flow-though cells
The RCMSi (Remote Calibration and Maintenance Service via the Internet) feature allows a calibrated measurement to be taken using an ISO 17025 certified liquid standard. The spectral response is transmitted to The Tintometer Ltd’s secure calibration server. On completion of this procedure, a traceable calibration certificate is emailed to the user. A set of standards is included with each meter to allow one RCMSi check at no cost. Subsequent RCMSi checks would be chargeable.
Specifications
- Catalog No:
- 633-0217
- 633-0216
- 633-0215
- 633-0214
- 633-0221
- 633-0220
- 633-0219
- 633-0213
- Model:
- PFXi 195
- PFXi 195
- PFXi 195
- PFXi 195
- PFXi 195
- PFXi 195
- PFXi 195
- PFXi 195
- Light source:
- 5 V, 10 W tungsten halogen lamp
- 5 V, 10 W tungsten halogen lamp
- 5 V, 10 W tungsten halogen lamp
- 5 V, 10 W tungsten halogen lamp
- 5 V, 10 W tungsten halogen lamp
- 5 V, 10 W tungsten halogen lamp
- 5 V, 10 W tungsten halogen lamp
- 5 V, 10 W tungsten halogen lamp
- Illuminants:
- CIE A, B, C, D65
- CIE A, B, C, D65
- CIE A, B, C, D65
- CIE A, B, C, D65
- CIE A, B, C, D65
- CIE A, B, C, D65
- CIE A, B, C, D65
- CIE A, B, C, D65
- Optical design:
- 9 interference filters
- 9 interference filters
- 9 interference filters
- 9 interference filters
- 9 interference filters
- 9 interference filters
- 9 interference filters
- 9 interference filters
- Range:
- 420 - 710 nm
- 420 - 710 nm
- 420 - 710 nm
- 420 - 710 nm
- 420 - 710 nm
- 420 - 710 nm
- 420 - 710 nm
- 420 - 710 nm
- Spectral bandwidth:
- 20 nm
- 20 nm
- 20 nm
- 20 nm
- 20 nm
- 20 nm
- 20 nm
- 20 nm
- Reproducibility:
- Chromaticity (x y) ±0,0004
- Chromaticity (x y) ±0,0004
- Chromaticity (x y) ±0,0004
- Chromaticity (x y) ±0,0004
- Chromaticity (x y) ±0,0004
- Chromaticity (x y) ±0,0004
- Chromaticity (x y) ±0,0004
- Chromaticity (x y) ±0,0004
- Measurement time:
- Less than 20 s
- Less than 20 s
- Less than 20 s
- Less than 20 s
- Less than 20 s
- Less than 20 s
- Less than 20 s
- Less than 20 s
- Path length:
- 0,1 - 50 mm
- 0,1 - 50 mm
- 0,1 - 50 mm
- 0,1 - 50 mm
- 0,1 - 50 mm
- 0,1 - 50 mm
- 0,1 - 50 mm
- 0,1 - 50 mm
- Display:
- LCD, 240×128, backlit graphic display (white on blue)
- LCD, 240×128, backlit graphic display (white on blue)
- LCD, 240×128, backlit graphic display (white on blue)
- LCD, 240×128, backlit graphic display (white on blue)
- LCD, 240×128, backlit graphic display (white on blue)
- LCD, 240×128, backlit graphic display (white on blue)
- LCD, 240×128, backlit graphic display (white on blue)
- LCD, 240×128, backlit graphic display (white on blue)
- Keyboard:
- 23 key tactile membrane keypad
- 23 key tactile membrane keypad
- 23 key tactile membrane keypad
- 23 key tactile membrane keypad
- 23 key tactile membrane keypad
- 23 key tactile membrane keypad
- 23 key tactile membrane keypad
- 23 key tactile membrane keypad
- Data storage:
- 100000+
- 100000+
- 100000+
- 100000+
- 100000+
- 100000+
- 100000+
- 100000+
- Calibration:
- Baseline: Single-key press, fully automated
- Baseline: Single-key press, fully automated
- Baseline: Single-key press, fully automated
- Baseline: Single-key press, fully automated
- Baseline: Single-key press, fully automated
- Baseline: Single-key press, fully automated
- Baseline: Single-key press, fully automated
- Baseline: Single-key press, fully automated
- Interfaces:
- USB, LAN, RS232C ports
- USB, LAN, RS232C ports
- USB, LAN, RS232C ports
- USB, LAN, RS232C ports
- USB, LAN, RS232C ports
- USB, LAN, RS232C ports
- USB, LAN, RS232C ports
- USB, LAN, RS232C ports
- Power requirements:
- 90 - 240 V
- 90 - 240 V
- 90 - 240 V
- 90 - 240 V
- 90 - 240 V
- 90 - 240 V
- 90 - 240 V
- 90 - 240 V
- W×D×H:
- 435×195×170 mm
- 435×195×170 mm
- 435×195×170 mm
- 435×195×170 mm
- 435×195×170 mm
- 435×195×170 mm
- 435×195×170 mm
- 435×195×170 mm
- Weight:
- 6,8 kg
- 6,8 kg
- 6,8 kg
- 6,8 kg
- 6,8 kg
- 6,8 kg
- 6,8 kg
- 6,8 kg
Specifications
Product Information
- Catalog #Supplier #ForPkAvailabilityPrice
- PFXi195/5 European/US Pharmacopoeia; Pt-Co/Hazen/ APHA; CIE Values; spectral dataPFXi195/5 European/US Pharmacopoeia; Pt-Co/Hazen/ APHA; CIE Values; spectral data633-02171371955Pharmaceutical solutions1Log in for availability1 * 1 pezzi9 780,00 €Specifications:
More
Accessories
Specifications
ModelPFXi 195Light source5 V, 10 W tungsten halogen lampEnvironmentally PreferableIlluminantsCIE A, B, C, D65Optical design9 interference filtersRange420 - 710 nmSpectral bandwidth20 nmReproducibilityChromaticity (x y) ±0,0004Measurement timeLess than 20 sPath length0,1 - 50 mmDisplayLCD, 240×128, backlit graphic display (white on blue)Keyboard23 key tactile membrane keypadData storage100000+CalibrationBaseline: Single-key press, fully automatedInterfacesUSB, LAN, RS232C portsPower requirements90 - 240 VW×D×H435×195×170 mmWeight6,8 kg - PFXi195/4 EBC (CIE &430 nm); ASBC (CIE &430 nm); Series 52 (Brown); CIE Values; spectral dataPFXi195/4 EBC (CIE &430 nm); ASBC (CIE &430 nm); Series 52 (Brown); CIE Values; spectral data633-02161371954Beers, malts & caramels1Log in for availability1 * 1 pezzi9 290,00 €Specifications:
More
Accessories
Specifications
ModelPFXi 195Light source5 V, 10 W tungsten halogen lampEnvironmentally PreferableIlluminantsCIE A, B, C, D65Optical design9 interference filtersRange420 - 710 nmSpectral bandwidth20 nmReproducibilityChromaticity (x y) ±0,0004Measurement timeLess than 20 sPath length0,1 - 50 mmDisplayLCD, 240×128, backlit graphic display (white on blue)Keyboard23 key tactile membrane keypadData storage100000+CalibrationBaseline: Single-key press, fully automatedInterfacesUSB, LAN, RS232C portsPower requirements90 - 240 VW×D×H435×195×170 mmWeight6,8 kg - PFXi195/3 FAC; Gardner; CIE values; spectral dataPFXi195/3 FAC; Gardner; CIE values; spectral data633-02151371953Dark oils & Fats1Log in for availability1 * 1 pezzi9 290,00 €Specifications:
More
Accessories
Specifications
ModelPFXi 195Light source5 V, 10 W tungsten halogen lampEnvironmentally PreferableIlluminantsCIE A, B, C, D65Optical design9 interference filtersRange420 - 710 nmSpectral bandwidth20 nmReproducibilityChromaticity (x y) ±0,0004Measurement timeLess than 20 sPath length0,1 - 50 mmDisplayLCD, 240×128, backlit graphic display (white on blue)Keyboard23 key tactile membrane keypadData storage100000+CalibrationBaseline: Single-key press, fully automatedInterfacesUSB, LAN, RS232C portsPower requirements90 - 240 VW×D×H435×195×170 mmWeight6,8 kg - PFXi195/2 Saybolt; ASTM Colour; Pt-Co/Hazen/APHA; CIE Values; spectral dataPFXi195/2 Saybolt; ASTM Colour; Pt-Co/Hazen/APHA; CIE Values; spectral data633-02141371952Petroleum oils & fuels1Log in for availability1 * 1 pezzi9 780,00 €Specifications:
More
Accessories
Specifications
ModelPFXi 195Light source5 V, 10 W tungsten halogen lampEnvironmentally PreferableIlluminantsCIE A, B, C, D65Optical design9 interference filtersRange420 - 710 nmSpectral bandwidth20 nmReproducibilityChromaticity (x y) ±0,0004Measurement timeLess than 20 sPath length0,1 - 50 mmDisplayLCD, 240×128, backlit graphic display (white on blue)Keyboard23 key tactile membrane keypadData storage100000+CalibrationBaseline: Single-key press, fully automatedInterfacesUSB, LAN, RS232C portsPower requirements90 - 240 VW×D×H435×195×170 mmWeight6,8 kg - PFXi195/9 CIE values (standard selection); L*C*h colour space; Hunter L a b colour space; spectral dataPFXi195/9 CIE values (standard selection); L*C*h colour space; Hunter L a b colour space; spectral data633-02211371959Transparent samples1Log in for availability1 * 1 pezzi8 650,00 €Specifications:
More
Accessories
Specifications
ModelPFXi 195Light source5 V, 10 W tungsten halogen lampEnvironmentally PreferableIlluminantsCIE A, B, C, D65Optical design9 interference filtersRange420 - 710 nmSpectral bandwidth20 nmReproducibilityChromaticity (x y) ±0,0004Measurement timeLess than 20 sPath length0,1 - 50 mmDisplayLCD, 240×128, backlit graphic display (white on blue)Keyboard23 key tactile membrane keypadData storage100000+CalibrationBaseline: Single-key press, fully automatedInterfacesUSB, LAN, RS232C portsPower requirements90 - 240 VW×D×H435×195×170 mmWeight6,8 kg - PFXi195/8 ADMI (spectral & tristimulus filter methods); Pt-Co/Hazen/APHA; CIE values; spectral dataPFXi195/8 ADMI (spectral & tristimulus filter methods); Pt-Co/Hazen/APHA; CIE values; spectral data633-02201371958Waters & wastewaters1Log in for availability1 * 1 pezzi9 290,00 €Specifications:
More
Accessories
Specifications
ModelPFXi 195Light source5 V, 10 W tungsten halogen lampEnvironmentally PreferableIlluminantsCIE A, B, C, D65Optical design9 interference filtersRange420 - 710 nmSpectral bandwidth20 nmReproducibilityChromaticity (x y) ±0,0004Measurement timeLess than 20 sPath length0,1 - 50 mmDisplayLCD, 240×128, backlit graphic display (white on blue)Keyboard23 key tactile membrane keypadData storage100000+CalibrationBaseline: Single-key press, fully automatedInterfacesUSB, LAN, RS232C portsPower requirements90 - 240 VW×D×H435×195×170 mmWeight6,8 kg - PFXi195/7 ICUMSA Colour (420, 560, 710 nm); Honey Colour (Pfund Equivalents); Series 52 (Brown); CIE values; spectral dataPFXi195/7 ICUMSA Colour (420, 560, 710 nm); Honey Colour (Pfund Equivalents); Series 52 (Brown); CIE values; spectral data633-02191371957Sugar solutions, syrups & honey1Log in for availability1 * 1 pezzi9 290,00 €Specifications:
More
Accessories
Specifications
ModelPFXi 195Light source5 V, 10 W tungsten halogen lampEnvironmentally PreferableIlluminantsCIE A, B, C, D65Optical design9 interference filtersRange420 - 710 nmSpectral bandwidth20 nmReproducibilityChromaticity (x y) ±0,0004Measurement timeLess than 20 sPath length0,1 - 50 mmDisplayLCD, 240×128, backlit graphic display (white on blue)Keyboard23 key tactile membrane keypadData storage100000+CalibrationBaseline: Single-key press, fully automatedInterfacesUSB, LAN, RS232C portsPower requirements90 - 240 VW×D×H435×195×170 mmWeight6,8 kg - PFXi195/1 Pt-Co/Hazen/APHA; Gardner; Iodine; CIE Values; spectral dataPFXi195/1 Pt-Co/Hazen/APHA; Gardner; Iodine; CIE Values; spectral data633-02131371951Liquid chemicals & industrial oils1Log in for availability1 * 1 pezzi9 290,00 €Specifications:
More
Accessories
Specifications
ModelPFXi 195Light source5 V, 10 W tungsten halogen lampEnvironmentally PreferableIlluminantsCIE A, B, C, D65Optical design9 interference filtersRange420 - 710 nmSpectral bandwidth20 nmReproducibilityChromaticity (x y) ±0,0004Measurement timeLess than 20 sPath length0,1 - 50 mmDisplayLCD, 240×128, backlit graphic display (white on blue)Keyboard23 key tactile membrane keypadData storage100000+CalibrationBaseline: Single-key press, fully automatedInterfacesUSB, LAN, RS232C portsPower requirements90 - 240 VW×D×H435×195×170 mmWeight6,8 kg
Optical glass cells
Product Information
- Catalog #SeqDescriptionForPkAvailabilityPrice
- 21Optical glass cell 2,5 mm path lengthLovibond® PFX and PFXi spectrophotometric colorimeters1Log in for availability
Conformance filters
Product Information
- Catalog #SeqDescriptionForPkPriceAvailabilityPrice
- 39EP brown series filter set - (2 filters: B2, B5)Lovibond® PFX and PFXi spectrophotometric colorimeters1516,00Log in for availability
Borosilicate glass cells
Product Information
- Catalog #SeqDescriptionForPkAvailabilityPrice
- 47Borosilicate glass cell, 10 mm path lengthLovibond® PFX and PFXi spectrophotometric colorimeters1Log in for availability
Colour scale upgrades
Product Information
- Catalog #SeqDescriptionForPkAvailabilityPrice
Certified colour reference standards- RCMSi
Product Information
- Catalog #SeqDescriptionForPkAvailabilityPrice