Environmental test chambers, MKF series
Supplier: Binder
Certificates
About this item
The MKF series of dynamic climate chambers has been specially developed as precision heating and cooling chambers for industrial material testing and environment simulation applications. The units are ideal for rapid temperature changes with humidity control and have a higher capacity which exceeds the capability of normal testing chambers. The stainless steel inner chamber has door heating, a heated viewing window with LED interior lighting and programmable condensation protection for the test materials.
- MCS controller can activate four zero-voltage relay contacts
- APT line™ preheating chamber technology and air conditioning technology provides spatial temperature and humidity values for total working area
- Integrated 20 L water-storage tank, with alarm notification in the event of insufficient water in fresh water tank
- User friendly colour LCD screen and easy to read menu guide, real time clock and integrated electronic chart recorder
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
- Electronically controlled humidification and dehumidification system with capacitive humidity sensor
- Adjustable ramp function, PT100 temperature sensor and CFC-free refrigerant R-404A
Certifications: IP protection class according to DIN EN 60529: IP 20. Conform to DIN EN 60068-2-30: 2006-06, DIN EN 60068-2-38: 2010-06, DIN EN 60068-3-5:2002-12 and MIL STD 810:2000-01
Delivery: Supplied with one stainless steel shelf, Binder test certificate, cooling with compressor cooling unit, evaporator, CFC-free refrigerant R-404A, four castors, two with brakes, thermal insulation, PT 100 temperature sensor and APT-COM™ 3 Basic edition communication software. Units have an Ethernet interface, 50 mm Ø access port with silicone plug on the left and are supplied with a safety connection kit for water supply and drainage up to 1 m height. A wide range of accessories are available, calibration and validation is possible, for details please visit www.vwr.com or contact your local Avantor sales office. Please note all MKF units require a three phase supply.
Specifications
- Catalog No:
- BIND9020-0381
- BIND9020-0379
- BIND9020-0380
- BIND9020-0378
- 390-1670
- 390-1669
- Model:
- MKF 720
- MKF 115
- MKF 240
- MKF 56
- MKF 1020
- MKF 400
- Temperature range:
- -40…+180 °C (without humidity), 10…95 °C (with humidity)
- -40…+180 °C (without humidity), 10…95 °C (with humidity)
- -40…+180 °C (without humidity), 10…95 °C (with humidity)
- -40…+180 °C (without humidity), 10…95 °C (with humidity)
- -40…+180 °C (without humidity), 10…95 °C (with humidity)
- -40…+180 °C (without humidity), 10…95 °C (with humidity)
- Temperature variation (spatial):
- 0,1...1,8 °C @ 25 °C
- 0,1...1,3 °C @ 25 °C
- 0,1...1,5 °C @ 25 °C
- 0,5...1,5 °C @ 25 °C
- 0,1...1,8 °C @ 25 °C
- 0,1...1,2 °C @ 25 °C
- Temperature fluctuation (time):
- 0,1...0,5 °C @ 25 °C
- 0,1...0,5 °C @ 25 °C
- 0,1...0,5 °C @ 25 °C
- 0,1...0,5 °C @ 25 °C
- 0,1...0,5 °C @ 25 °C
- 0,1...0,5 °C @ 25 °C
- Temperature sensor:
- -40...+180 °C (without humidity), 10...95 °C (with humidity)
- Humidity range:
- 10 - 98 %RH
- 10 - 98 %RH
- 10 - 98 %RH
- 10 - 98 %RH
- 10 - 98 %RH
- 10 - 98 %RH
- Capacity:
- 734 L
- 115 L
- 228 L
- 60 L
- 991 L
- 417 L
- Convection type:
- Forced convection
- Forced convection
- Forced convection
- Forced convection
- Forced convection
- Forced convection
- Max. load per shelf:
- 40 kg
- 30 kg
- 30 kg
- 15 kg
- 40 kg
- 30 kg
- Shelves supplied (max.):
- 1 (11)
- 1 (4)
- 1 (6)
- 1 (4)
- 1 (11)
- 1 (6)
- Int. W×D×H:
- 1200×600×1020 mm
- 600×400×480 mm
- 735×443×700 mm
- 400×348×420 mm
- 1200×810×1020 mm
- 735×810×700 mm
- Ext. W×D×H:
- 1580×1140×2005 mm
- 980×865×1725 mm
- 1115×925×1715 mm
- 720×780×1445 mm
- 1580×1480×2005 mm
- 1115×1400×1710 mm
- Nominal power consumption:
- 11000 W
- 4800 W
- 6800 W
- 2800 W
- 12500 W
- 8000 W
- Weight:
- 590 kg
- 280 kg
- 360 kg
- 175 kg
- 636 kg
- 432 kg
Specifications
Product Information
- Catalog #Supplier #TypePkAvailabilityPrice
- Specifications:
More
Accessories
Specifications
ModelMKF 56Temperature range-40…+180 °C (without humidity), 10…95 °C (with humidity)Environmentally PreferableTemperature variation (spatial)0,5...1,5 °C @ 25 °CTemperature fluctuation (time)0,1...0,5 °C @ 25 °CTemperature sensor-40...+180 °C (without humidity), 10...95 °C (with humidity)Humidity range10 - 98 %RHCapacity60 LConvection typeForced convectionMax. load per shelf15 kgShelves supplied (max.)1 (4)Int. W×D×H400×348×420 mmExt. W×D×H720×780×1445 mmNominal power consumption2800 WWeight175 kg - Specifications:
More
Accessories
Specifications
ModelMKF 115Temperature range-40…+180 °C (without humidity), 10…95 °C (with humidity)Environmentally PreferableTemperature variation (spatial)0,1...1,3 °C @ 25 °CTemperature fluctuation (time)0,1...0,5 °C @ 25 °CTemperature sensorHumidity range10 - 98 %RHCapacity115 LConvection typeForced convectionMax. load per shelf30 kgShelves supplied (max.)1 (4)Int. W×D×H600×400×480 mmExt. W×D×H980×865×1725 mmNominal power consumption4800 WWeight280 kg - Specifications:
More
Accessories
Specifications
ModelMKF 240Temperature range-40…+180 °C (without humidity), 10…95 °C (with humidity)Environmentally PreferableTemperature variation (spatial)0,1...1,5 °C @ 25 °CTemperature fluctuation (time)0,1...0,5 °C @ 25 °CTemperature sensorHumidity range10 - 98 %RHCapacity228 LConvection typeForced convectionMax. load per shelf30 kgShelves supplied (max.)1 (6)Int. W×D×H735×443×700 mmExt. W×D×H1115×925×1715 mmNominal power consumption6800 WWeight360 kg - Specifications:
More
Accessories
Specifications
ModelMKF 400Temperature range-40…+180 °C (without humidity), 10…95 °C (with humidity)Environmentally PreferableTemperature variation (spatial)0,1...1,2 °C @ 25 °CTemperature fluctuation (time)0,1...0,5 °C @ 25 °CTemperature sensorHumidity range10 - 98 %RHCapacity417 LConvection typeForced convectionMax. load per shelf30 kgShelves supplied (max.)1 (6)Int. W×D×H735×810×700 mmExt. W×D×H1115×1400×1710 mmNominal power consumption8000 WWeight432 kg - Specifications:
More
Accessories
Specifications
ModelMKF 720Temperature range-40…+180 °C (without humidity), 10…95 °C (with humidity)Environmentally PreferableTemperature variation (spatial)0,1...1,8 °C @ 25 °CTemperature fluctuation (time)0,1...0,5 °C @ 25 °CTemperature sensorHumidity range10 - 98 %RHCapacity734 LConvection typeForced convectionMax. load per shelf40 kgShelves supplied (max.)1 (11)Int. W×D×H1200×600×1020 mmExt. W×D×H1580×1140×2005 mmNominal power consumption11000 WWeight590 kg - Specifications:
More
Accessories
Specifications
ModelMKF 1020Temperature range-40…+180 °C (without humidity), 10…95 °C (with humidity)Environmentally PreferableTemperature variation (spatial)0,1...1,8 °C @ 25 °CTemperature fluctuation (time)0,1...0,5 °C @ 25 °CTemperature sensorHumidity range10 - 98 %RHCapacity991 LConvection typeForced convectionMax. load per shelf40 kgShelves supplied (max.)1 (11)Int. W×D×H1200×810×1020 mmExt. W×D×H1580×1480×2005 mmNominal power consumption12500 WWeight636 kg